Homogenisasi Sekunder terhadap Kadar Hemoglobin
Abstract
This study aims to determine the results of hemoglobin examination with secondary homogenization techniques 3, 5, 7, and 8 times, after being left for 60 minutes after primary homogenization. The research method used is pre-experimental research. The results showed that the average hemoglobin measured by an automatic hematology analyzer in the secondary homogenized blood group was 3 times 13.3 g/dl, homogenized 5 times 13.1 g/dl, homogenized 7 times 13.2 g/dl, and homogenization 8 times 13.1g/dl. In conclusion, there is no difference in hemoglobin levels in the secondary homogenization process 3, 5, 7, and 8 times.
Keywords: EDTA Blood, Hemoglobin, Homogenization
References
Alshaghdali, K., Alcantara, T. Y., Rezgui, R., Cruz, C. P., Alshammary, M. H., Almotairi, Y. A., & Alcantara, J. C. (2021). Detecting Preanalytical Errors Using Quality Indicators in a Hematology Laboratory. Quality Management in Health Care, 1–8. https://doi.org/10.1097/QMH.0000000000000343
Gupta, P., Thomas, M., Sbetan, N., Chacko, G., Savarimuthu, I., Cherian, P., Abas, A., Shiju, S., Karim, S., Kanaan, A., Bautista, G., Elsalasiny, N., Balushi, S. A., Haga, A. E., & Hassan, M. E. (2021). A Quality Improvement Initiative to Reduce Rejected Laboratory Samples and Enhance Specimen Acceptability. Joint Commission Journal on Quality and Patient Safety, 47(8), 519–525. https://doi.org/10.1016/j.jcjq.2021.04.005
Hartina, H., Garini, A., & Tarmizi, M. I. (2019). Perbandingan Teknik Homogenisasi Darah EDTA dengan Teknik Inversi dan Teknik Angka Delapan terhadap Jumlah Trombosit. JPP (Jurnal Kesehatan Poltekkes Palembang), 13(2), 150–153. https://doi.org/10.36086/jpp.v13i2.239
Kure, T., & Sakai, H. (2021). Preparation of Artificial Red Blood Cells (Hemoglobin Vesicles) Using the Rotation-Revolution Mixer for High Encapsulation Efficiency. ACS Biomaterials Science and Engineering, 7(6), 2835–2844. https://doi.org/10.1021/acsbiomaterials.1c00424
Lestari, A. I. (2019). Different Amount of Thrombocytes on Blood Storage for 24 Hours in Room and Refrigerator. Journal of Vocational Health Studies, 3(2), 59. https://doi.org/10.20473/jvhs.v3.i2.2019.59-62
Mustika, I., Hidayati L, S., Kusumawati, E., & Lusiana, N. (2019). Anemia Defisiensi Besi dan Indeks Massa Tubuh terhadap Siklus Menstruasi Remaja Putri. Jurnal Kesehatan, 12(1), 30–40. https://doi.org/10.24252/kesehatan.v12i1.7157
Ramadhani, Q. A. N., Garini, A., Nurhayati, N., & Harianja, S. H. (2019). Perbedaan Kadar Glukosa Darah Sewaktu Menggunakan Serum dan Plasma Edta. JPP (Jurnal Kesehatan Poltekkes Palembang), 14(2), 80–84. https://doi.org/10.36086/jpp.v14i2.407
Rosidah, R., & Wibowo, C. (2018). Perbedaan antara Pemeriksaan Antikoagulan EDTA dan Heparin terhadap Nilai Hematokrit (HCT). Jurnal Sains, 8(16), 16–21. http://journal.unigres.ac.id/index.php/Sains/article/view/800/671
Sari, D. P., & Darmadi, D. (2018). Perbedaan Jumlah Leukosit Darah Edta Diperiksa Segera dan Ditunda 2 Jam. Klinikal Sains : Jurnal Analis Kesehatan, 6(2), 30–36. http://jurnal.univrab.ac.id/index.php/klinikal/article/view/578
Simundic, A. M., Baird, G., Cadamuro, J., Costelloe, S. J., & Lippi, G. (2020). Managing Hemolyzed Samples in Clinical Laboratories. Critical Reviews in Clinical Laboratory Sciences, 57(1), 1–21. https://doi.org/10.1080/10408363.2019.1664391
Utami, A. P., Nurhayati, B., Noviar, G., & Durachim, A. (2019). Waktu Simpan Darah Antikoagulan K2EDTA dan K3EDTA terhadap Parameter Eritrosit. AIJ Journal of Technology and Design, 11(2), 178–189. https://doi.org/DOI: https://doi.org/10.34011/juriskesbdg.v11i2.743
Yucel, C., Turhan, T., & Calci, E. (2017). The Effect of Preanalytical Mechanical Mixing Time on Complete Blood Cell Count Parameters in the Emergency Laboratory. Medicine Science | International Medical Journal, 6(2). https://doi.org/10.5455/medscience.2016.05.8552
Copyright (c) 2021 Rosnita Sebayang, Hotman Sinaga, Mustika Sari Hutabarat
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.