Homogenisasi Sekunder terhadap Kadar Hemoglobin

  • Rosnita Sebayang Universitas Katolik Musi Charitas
  • Hotman Sinaga Universitas Katolik Musi Charitas
  • Mustika Sari Hutabarat Universitas Katolik Musi Charitas

Abstract

This study aims to determine the results of hemoglobin examination with secondary homogenization techniques 3, 5, 7, and 8 times, after being left for 60 minutes after primary homogenization. The research method used is pre-experimental research. The results showed that the average hemoglobin measured by an automatic hematology analyzer in the secondary homogenized blood group was 3 times 13.3 g/dl, homogenized 5 times 13.1 g/dl, homogenized 7 times 13.2 g/dl, and homogenization 8 times 13.1g/dl. In conclusion, there is no difference in hemoglobin levels in the secondary homogenization process 3, 5, 7, and 8 times.

 

Keywords: EDTA Blood, Hemoglobin, Homogenization

References

Aipassa, I., Rahayu, M., & Ariyadi, T. (2020). Perbedaan Kadar Ureum Serum dan Plasma Lithium Heparin. Jurnal Labora Medika, 4, 42–46. https://jurnal.unimus.ac.id/index.php/JLabMed/article/view/7220

Alshaghdali, K., Alcantara, T. Y., Rezgui, R., Cruz, C. P., Alshammary, M. H., Almotairi, Y. A., & Alcantara, J. C. (2021). Detecting Preanalytical Errors Using Quality Indicators in a Hematology Laboratory. Quality Management in Health Care, 1–8. https://doi.org/10.1097/QMH.0000000000000343

Gupta, P., Thomas, M., Sbetan, N., Chacko, G., Savarimuthu, I., Cherian, P., Abas, A., Shiju, S., Karim, S., Kanaan, A., Bautista, G., Elsalasiny, N., Balushi, S. A., Haga, A. E., & Hassan, M. E. (2021). A Quality Improvement Initiative to Reduce Rejected Laboratory Samples and Enhance Specimen Acceptability. Joint Commission Journal on Quality and Patient Safety, 47(8), 519–525. https://doi.org/10.1016/j.jcjq.2021.04.005

Hartina, H., Garini, A., & Tarmizi, M. I. (2019). Perbandingan Teknik Homogenisasi Darah EDTA dengan Teknik Inversi dan Teknik Angka Delapan terhadap Jumlah Trombosit. JPP (Jurnal Kesehatan Poltekkes Palembang), 13(2), 150–153. https://doi.org/10.36086/jpp.v13i2.239

Kure, T., & Sakai, H. (2021). Preparation of Artificial Red Blood Cells (Hemoglobin Vesicles) Using the Rotation-Revolution Mixer for High Encapsulation Efficiency. ACS Biomaterials Science and Engineering, 7(6), 2835–2844. https://doi.org/10.1021/acsbiomaterials.1c00424

Lestari, A. I. (2019). Different Amount of Thrombocytes on Blood Storage for 24 Hours in Room and Refrigerator. Journal of Vocational Health Studies, 3(2), 59. https://doi.org/10.20473/jvhs.v3.i2.2019.59-62

Mustika, I., Hidayati L, S., Kusumawati, E., & Lusiana, N. (2019). Anemia Defisiensi Besi dan Indeks Massa Tubuh terhadap Siklus Menstruasi Remaja Putri. Jurnal Kesehatan, 12(1), 30–40. https://doi.org/10.24252/kesehatan.v12i1.7157

Ramadhani, Q. A. N., Garini, A., Nurhayati, N., & Harianja, S. H. (2019). Perbedaan Kadar Glukosa Darah Sewaktu Menggunakan Serum dan Plasma Edta. JPP (Jurnal Kesehatan Poltekkes Palembang), 14(2), 80–84. https://doi.org/10.36086/jpp.v14i2.407

Rosidah, R., & Wibowo, C. (2018). Perbedaan antara Pemeriksaan Antikoagulan EDTA dan Heparin terhadap Nilai Hematokrit (HCT). Jurnal Sains, 8(16), 16–21. http://journal.unigres.ac.id/index.php/Sains/article/view/800/671

Sari, D. P., & Darmadi, D. (2018). Perbedaan Jumlah Leukosit Darah Edta Diperiksa Segera dan Ditunda 2 Jam. Klinikal Sains : Jurnal Analis Kesehatan, 6(2), 30–36. http://jurnal.univrab.ac.id/index.php/klinikal/article/view/578

Simundic, A. M., Baird, G., Cadamuro, J., Costelloe, S. J., & Lippi, G. (2020). Managing Hemolyzed Samples in Clinical Laboratories. Critical Reviews in Clinical Laboratory Sciences, 57(1), 1–21. https://doi.org/10.1080/10408363.2019.1664391

Utami, A. P., Nurhayati, B., Noviar, G., & Durachim, A. (2019). Waktu Simpan Darah Antikoagulan K2EDTA dan K3EDTA terhadap Parameter Eritrosit. AIJ Journal of Technology and Design, 11(2), 178–189. https://doi.org/DOI: https://doi.org/10.34011/juriskesbdg.v11i2.743

Yucel, C., Turhan, T., & Calci, E. (2017). The Effect of Preanalytical Mechanical Mixing Time on Complete Blood Cell Count Parameters in the Emergency Laboratory. Medicine Science | International Medical Journal, 6(2). https://doi.org/10.5455/medscience.2016.05.8552
Published
2021-12-26
Abstract viewed = 107 times