Analisis Aktivitas Kontraksi Uterus dan Perinatal Outcome pada Ibu Bersalin dengan Induksi

  • Shinta Wurdiana Rhomadona Jurusan Kebidanan, Magister Terapan Kesehatan, Poltekkes Kemenkes Semarang
  • Melyana Nurul Widyawati Jurusan Kebidanan, Magister Terapan Kesehatan, Poltekkes Kemenkes Semarang

Abstract

The purpose of this study was to analyze the activity of uterine contractions and perinatal outcomes in mothers with induction. This research method was a prospective observational descriptive design for 20 women giving birth by induction monitored every 15 minutes for 10 minutes by palpation and recorded the perinatal outcome. The monitoring results are calculated on average frequency and duration and then presented in the form of trends. The results of this study show the trend of frequency and duration of labor with induction that succeed in having a rhythm tends to increase while the failure tends to be constant. Successful frequency and duration of induction were successful 4.2 times / 10 minutes and 45.09 seconds. While the failed induction is 1.92 times / 10 minutes and 25.54 seconds. Of the 20 respondents, most of them were between 2500-4000 grams, which amounted to 19 babies. The sex of the majority of women is 11 babies. Apgar condition scores between 7-10 that is equal to 16 babies. 1 serotinus baby and no baby with pathological jaundice.

 Keywords: induction labor, perinatal outcome, uterine contraction activity

References

Akare, m. D. & Patel, p. K. (2017). A Comparison of Sublingual with Vaginal Administration of Misoprostol for Induction of Labor at Term. International Journal of Reproduction, Contraception, Obstetrics and Gynecology, 6: 1398-1403.

Apn. (2011). Asuhan Persalinan Normal dan Inisiasi Menyusui Dini. Jakarta, JNPK-kr.
Arias, f. (2000). Pharmacology of Oxytocin and Prostaglandins. Clinical Obstetrics and gynecology, 43: 455-468.

Bainuan, l. D., Husin, f., Anwar, a. D., Arifin, a. & Wirakusumah, f. F. (2018). Sensitivitas, Spesifisitas dan Akurasi Pengukuran Kontraksi Uterus Kala I Fase Aktif Ibu Bersalin menggunakan Tokodinamometer. Majalah Kedokteran Bandung, 50: 29-35.

Bakker, p. C., Van Rijswijk, s. & Van Geijn, h. P. (2008). Uterine Activity Monitoring during Labor. Journal of Perinatal Medicine, 36: 184-184.

Bomba-opoń, d., Drews, k., Huras, h., Laudański, p., Paszkowski, t. P. & Wielgoś, m. (2017). Polish Gynecological Society Recommendations for Labor Induction. Ginekologia Polska, 88: 224-234.

Bujold, e., Blackwell, s. C., Hendler, i., Berman, s., Sorokin, y. & Gauthier, r. J. (2004). Modified Bishop's Score and Induction of Labor in Patients with a Previous Cesarean Delivery. American Journal of Obstetrics and Gynecology, 191: 1644-1648.

Cunningham, Gant, Leveno, Gilstrap, Hauth & Wenstrom. (2001). Obstetri Williams,vol 2. Jakarta: EGC.

Dania, H., Wahyono, D. & Retnowati, S. (2014). Perbandingan Efektivitas Misoprostol Dosis 50 µG dan 100 µG Terhadap Keberhasilan Kelahiran Induksi di RSU PKU Muhammadiyah Yogyakarta. Pharmaciana, 4.

Dewi, i. P. & Salmiyati, z. (2016). Evaluasi Penggunaan Misoprostol pada Kehamilan Postterm di Bangsal Kebidanan RSUP dr. M. Djamil Padang. Jurnal Ipteks Terapan, 10: 170-175.

Fraser, d. M. & Cooper, m. A. (2009). Buku Ajar Bidan Myles, Edisi 14. Jakarta: EGC.

Garfield, r. E. & Maner, w. L. (2007). Physiology and Electrical Activity of Uterine Contractions. Seminars in Cell & Developmental Biology. Elsevier, 289-295.

Gommers, j. S., Diederen, m., Wilkinson, c., Turnbull, d. & Mol, b. W. (2017). Risk of Maternal, Fetal and Neonatal Complications Associated with the Use of the Transcervical Balloon Catheter in Induction of Labour: a Systematic review. European Journal of Obstetrics and Gynecology and Reproductive Biology. 218, 73-84.

Grobman, w. A., Bailit, j., Lai, y., Reddy, u. M., Wapner, r. J., Varner, m. W., Thorp, j. M., Leveno, k. J., Caritis, s. N., Prasad, m., Tita, a. T. N., Saade, g., Sorokin, y., Rouse, d. J., Blackwell, s. C. & Tolosa, j. E. (2018). Defining Failed Induction of Labor. American Journal of Obstetrics and Gynecology, 218, 122.e1-122.e8.

Hadar, e., Melamed, n., Aviram, a., Raban, o., Saltzer, l., hiersch, l. & Yogev, y. (2013). Effect of an Oxytocin Receptor Antagonist (Atosiban) on Uterine Electrical Activity. American Journal of Obstetrics and Gynecology, 209. 384. E1-384. E7.

Harjanto, a. R. & Muhartono, m. (2015). Korelasi antara Pemakaian Oksitosin Drip pada Ibu dengan Angka Kejadian Hiperbilirubinemia Neonatal. Jurnal Agromedicine, 2, 278-283.

Jordan, s. (2011). Farmakologi kebidanan. Jakarta: EGC.

Lasmini, p. S., Yunitra, i. & Bachtiar, h. (2017). Perbedaan Efek Misoprostol dan Oksitosin sebagai Pematangan Serviks. Andalas Obstetric and Gynecology Journal, 2.

Leduc, d., Biringer, a., Lee, l., Dy, j., Corbett, t., Duperron, l., Lange, i., Muise, s., Parish, b. & Regush, l. (2013). Induction of Labour. Journal of Obstetrics and Gynaecology Canada, 35, 840-857.

Mcdermott, i., Saade, g., Garfield, r. & Thornton, s. (2005). Uterine EMG Activity in Women Who do and do not Progress in Labour. American Journal of Obstetrics and Gynecology, 193, s47.

Meliyana, e. (2018). Hubungan Induksi Persalinan dengan Resiko Kejadian Asfiksia Neonatorum di RSUD Kabupaten Bekasi Periode September-November Tahun 2011. Jurnal Ayurveda, 1.

Mozurkewich e, c. J., Koepke e, Keeton k, King vj. (2009). Indications for Induction of Labour: a Best-Evidence Review. Pubmed, 626-36.

Prawirohardjo, s. & Saifuddin, a. B. (2014). Ilmu Kebidanan, Jakarta, Yayasan Bina Pustaka Sarwono Prawirohardjo.

Putri, m. S., Titisari, i. & Setyarini, a. I. (2017). Hubungan Usia Kehamilan dengan Komplikasi pada Bayi Baru Lahir di RS Aura Syifa Kabupaten Kediri Tahun 2017. Jurnal Ilmu Kesehatan, 6, 101-108.

Ryan, r. & Mccarthy, f. (2016). Induction of Labour. Obstetrics, Gynaecology & Reproductive Medicine, 26, 304-310.

Saifuddin, a. B. (2010). Buku Acuan Nasional Pelayanan Kesehatan Maternal dan Neonatal, Jakarta, Yayasan Bina Pustaka Sarwono Prawirohardjo.

Santy, t. A., Suryono & Nurul, m. (2017). Aktivitas Kelistrikan Uterus pada Kontraksi Persalinan Kala 1. Master, Semarang Health Polytechnic.

Simpson, k. R. & James, d. C. (2008). Effects of Oxytocin-Induced Uterine Hyperstimulation during Labor on Fetal Oxygen Status and Fetal Heart Rate Patterns. American Journal of Obstetrics and Gynecology, 199, 34. E1-34. E5.

Tang, o., Gemzell‐Danielsson, k. & ho, p. (2007). Misoprostol: Pharmacokinetic Profiles, Effects on the Uterus and Side‐Effects. International Journal of Gynecology & Obstetrics, 99.

Tenore, j. L. (2006). Methods for Cervical Ripening and Induction of Labor. American Family Physician, 67, 2123-2128.

Varney, h., Kriebs, j. M. & l, c. (2007). Buku Ajar Asuhan Kebidanan,Edisi 4, Jakarta: EGC.

Who. (2011). Who Recommendations for Induction of Labour, Geneva: World Health Organization.

Who. (2014). Who Recommendations for Augmentation of Labour, World Health organization.

William a. Grobman, j. B., Yinglei lai, UMA m. Reddy, Ronald j. Wapner, michael w. Varner, John m. Thorp, Kenneth j. Leveno, Steve n. Caritis, Mona Prasad, Alan t.n. Tita, George Saade, Yoram Sorokin, Dwight j. Rouse, sean c. Blackwell, jorge e. Tolosa. (2017). Defining failed induction of Labor, in American Journal of Obstetrics and Gynecology. American Journal of Obstetrics and Gynecology
Published
2019-05-13
How to Cite
Rhomadona, S., & Widyawati, M. (2019). Analisis Aktivitas Kontraksi Uterus dan Perinatal Outcome pada Ibu Bersalin dengan Induksi. Jurnal Keperawatan Silampari, 2(2), 53-65. https://doi.org/https://doi.org/10.31539/jks.v2i2.517
Abstract viewed = 33 times
pdf downloaded = 72 times